Description
FEATURES
Quick and easy
- Easy integration of devices
- Centralized commissioning of all integrated components
Future-proof and flexible
- Flexibly expandable anytime
- Access to the energy market of the future based on ennexOS
Functional
- Complies with international grid integration requirements
- Combine storage systems, energy generators and e-mobility
Reliable and convenient
- Remote monitoring and parameterization possible
- Detailed analytics, error messages and reporting through Sunny Portal
SPECIFICATION
Technical data | SMA DATA MANAGER M |
Master data | |
Total number of supported devices - of which: | 50 |
Maximum number of supported PV inverters | 50 |
Maximum number of supported PV inverters via Modbus Sunspec (e.g., SMA CORE2) | 20 |
Maximum number of supported battery inverters | 50 |
Maximum number of supported energy meters (electric current and gas), generators from energy meters, I/O systems, sensors |
50 |
Maximum system power PV inverters (nominal AC power) | 2.5 MVA (Closed-loop control) 7.5 MVA (Open-loop control or only monitoring) |
Maximum system power battery inverters (nominal AC power)
|
2.5 MVA (Closed-loop control) 7.5 MVA (Open-loop control or only monitoring) |
Automatic data recording for virtual generators from energy meters (PV inverter, combined heat and power plant, gas meter, diesel generator, hydroelectric power plant) |
● |
Connections | |
Voltage supply | 2-pin connection, MINI COMBICON |
RS485 | 6-pin connection, MINI COMBICON |
Network (LAN) | 2 x RJ45, switched, 10 BaseT/100 BaseT |
USB (for product updates) | 1 x USB 2.0, type A |
WLAN access point for commissioning and access to the user interface | ▲ |
Voltage supply | |
Voltage supply |
External power supply unit (available as an accessory)
|
Input voltage | 10 V to 30 V DC |
Power consumption | Typically 4 W |
Ambient conditions during operation | |
Environment | Restricted class 3K7 reg. IEC60721-3-3 |
Ambient temperature | –20 °C to +60 °C |
Permissible range for relative humidity (non-condensing) | 5% to 95% |
Maximum operating altitude above MSL | 0 m to 3,000 m (≥70 kPa) |
Degree of protection according to IEC 60529 | IP20 (NEMA 1) |
General data | |
Dimensions (W/H/D) | 161.1 mm / 89.7 mm / 67.2 mm |
Weight | 220 g |
Mounting location | Indoors |
Mounting type | Top-hat rail mounting / wall mounting |
Status display | LEDs for system and communication status |
Features | |
Warranty | 2 years |
Accessories (optional) | |
Top-hat rail power supply unit |
Input: 100 V to 240 V AC / 45 Hz to 65 Hz / Output: 24 V
|
Plug-in power supply | ● |
Communication / protocols | |
FTP push (daily / hourly) | ● / ● |
WLAN access to the customer network | - |
SMA Data2+ / SMA Data | ● / ● |
EtherLynx for Danfoss for TLX & FLX | ● |
Client: Modbus/RTU, Modbus/TCP (also Sunspec) | ● |
Server: Modbus/TCP | ● |
Commissioning | |
Assistant for local commissioning of connected devices | ● |
Assistant for parameterization of SMA products connected via Speedwire | ● |
Remote parameterization of SMA devices with Sunny Portal | ● |
Updates | |
Self-update and connected Speedwire devices via USB | ● |
Self-update and connected Speedwire devices via SMA Update Portal | ● |
Grid management services | |
Closed-loop control and open-loop control of other SMA Data Managers (master/slave) | ● |
Free configuration of a grid-connection meter (measurement at the point of interconnection) | ● |
Direct selling via SMA SPOT (Germany) | ● |
Various options for open-loop and closed-loop control of active and reactive power | ● |
Manual inputs or inputs transferred via Modbus | ● |
Specifications via analog and digital inputs | via external I/O systems |
Open-loop and closed-loop active power control (digital inputs) | ● |
Closed-loop active power control (P(f)) | in the SMA inverter |
Open-loop and closed-loop reactive power control (Q(V)) | ● |
Fast shutdown via the digital input | ● |
● Standard features ○ Optional features — Not available ▲ Depending on availability |