Description
FEATURES
- Multistage Charging: Fully automatic multistage battery charger with the ability to charge 3 separate battery banks
- Separate Battery Banks: Isolated charging design where battery bank one is separate from battery bank two and three
- Programmable: Battery bank 1 can be programmed with a different charge algorithm over banks 2 and 3
- Current Control: User adjustable current output (e.g. Dial the 60amp unit back to run off a 1kVA generator)
- Smart Charging: The ePOWER battery charger will regulate its output based on the loads connected to your battery banks
- Wide AC Input Range: Operates on both 110V / 60Hz and 240V / 50Hz
- LED Display: Easy to use “set and select” menu along with scrolling charger status
- Silent Mode: Disables the cooling fan for total silent operation at night or whenever required. Activation reduces charge output by half and locks out fan for 12 hours
- Temperature Sensor: Battery temperature sensor included with 3-meter cable
- 5 Year Warranty from an Australian company renowned for customer support
PACKAGE INCLUDED:
- 1 x Battery Charger
- 1 x 3-Meter Cable
- 1 x Manual
SPECIFICATIONS
Model | EN31220 | EN31240 | EN31260 | EN32430 |
---|---|---|---|---|
CHARGER OUTPUT | ||||
Output Current (Maximum) | 20A | 40A | 60A | 30A |
OUTPUT VOLTAGE RANGE | ||||
Charge | 14.2 – 15.5 V | 28.4 – 31.0V | ||
Float | 13.4 – 13.8 V | 26.8 – 27.6V | ||
– Equalize | 16.0 V | 32.0V | ||
Charging Control | Four stages (Bulk/Absorption/Float/Maintenance) | |||
Two stages (Bulk/Absorption) | ||||
Constant Power Supply (Program setting) | ||||
Priority Battery Bank Charging | ||||
DC Output Bank | Three (1 fully independent, 2 common with diode isolation) | |||
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program | |||
Standby Current | < 2 mA | |||
CHARGER INPUT | ||||
AC Input Voltage (Nominal) | 90 to 265 VAC | |||
AC Input Operating Range | 207-265 Vac (2.0 A Max)90-125 Vac (3.8 A Max) | 207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max) | 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) | 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) |
AC Input Frequency Range | 47 – 63 Hz | |||
Power Consumption | 350W (Full Load) | 700W (Full Load) | 1050W (Full Load) | 1050W (Full Load) |
Power Factor Correction | Yes | |||
Charger Efficiency | > 82% | |||
PROTECTION AND FEATURES | ||||
Reverse Polarity | Yes, (with user replaceable fuse/s) | |||
Over Charge | Yes, unit shutdown | |||
Over Temperature | Yes, unit de-rated and shutdown | |||
Output Short Circuit | Yes, (with user replaceable fuse/s) | |||
Cooling | Forced air ventilation (thermo controlled fan) | |||
Temperature Setting | Hot, Normal, Cold (no sensor connected) | |||
Battery Temp Sensor Port | RJ12 (standard battery temp. sensor supplied) | |||
DISPLAY | ||||
LCD Display (with back light) | Charging status, Battery Voltage, Output Current & Fault Codes. | |||
AC INPUT AND DC OUTPUT CONNECTION | ||||
AC Input Connection | IEC with Supplied 1.2M Power Lead | |||
DC Output Connection | Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread | |||
DC Output Ground | Single Heavy Duty Common Ground Stud | |||
ENVIRONMENTAL AND OPERATING TEMPERATURE | ||||
Storage Range | -40° to 70° C | |||
Operating Range | -20° to 60° C | |||
Humidity | 5-95%, relative humidity non-condensing | |||
Ingress Protection | IP32 (Basic drip proof in vertical orientation) | |||
Base Unit Weight and Dimensions | ||||
Weight: (kg) | 2.4 | 2.6 | 4 | 4 |
Dimension: (mm) L x W x H | 295 x 206 x 86 | 295 x 206 x 86 | 356 x 206 x 99 | 356 x 206 x 99 |
Optional Accessories | Remote Digital Display / Enerdrive Part Number EN3REM | |||
Regulatory Compliance | Complies with AS/NZS 60335.2.29 Including Australian deviations. |