Battery Management system- The BMS connects to 12,8V Victron LiFePO4 (LFP) batteries. Up to 5 batteries may be connected in parallel. Can be used as a system on/off switch.
Starter battery Protection- This function is similar to that of a Cyrix Battery Combiner or Argo FET Battery Isolator. Current can flow to the LFP battery only if the input voltage (= voltage on the starter battery) exceeds 13V.
Alternator and battery protection- The input current is electronically limited to approximately 90% of the fuse rating.
Choosing the right fuse will:
A. Protect the LFP battery against excessive charge current (important in case of a low capacity LFP battery).
B. Protect the alternator against overload in case of a high capacity LFP battery bank (most 12V alternators will overheat and fail if running at maximum output during more than 5 minutes).
Load/battery charger output-input (Power Port SYSTEM+)- This Power Port can be used to either charge or discharge the LFP battery (i.e. via a charger, an inverter or inverter/charger) with a maximum continuous current of 200A in both directions.
-The Smart BMS will make sure that the battery discharge will cut-off in case of imminent cell under voltage.
-The Smart BMS will enable charging through this port, but no charge algorithm can be applied internally.
FEATURES
Li-ion battery protection- Excessive input voltage and transients are regulated down to a safe level. The Smart BMS will stop charging in case of cell over voltage or over temperature. It has three outputs, similar to the small BMS:
Load Disconnect output: The Load output is normally high and becomes free floating in case of imminent cell under voltage (default 2,8V/cell, adjustable on the battery between 2,6V and 2,8V per cell). Maximum current: 10mA.
Pre-Alarm output: The pre-alarm output can be used as warning when the battery voltage is low and it will trip shortly before the Load Disconnect output is disabled due to cell under voltage.
- The pre-alarm output may be used to drive a relay, LED or Buzzer. It can be configured as continuous or intermittent signal.
- The pre-alarm output is normally free floating and becomes high in case of imminent cell under voltage (default 3,1V/cell, adjustable on the battery between 2,85V and 3,15V per cell).
Charge disconnect output: The Charge disconnect output is normally high and becomes free floating in case of imminent cell over voltage or over temperature. Maximum current:10mA.
Remote on/off input- The remote on/off input controls the charging via the alternator. When off, charging via the alternator is disabled, while the BMS functionality will remain active allowing any loads and chargers to continue working regardless of the state of the remote input.
Ignition proof- No relays but MOSFET switches, and therefore, no sparks.
SPECIFICATIONS