Description
FEATURES
A MultiPlus, plus ESS (Energy Storage System) functionality- The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external current sensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A. The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications. It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
PowerControl and PowerAssist - Boosting the capacity of the grid or a generator- A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl function).
Solar energy: AC power available even during a grid failure- The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is compatible with both solar charger controllers and grid-tie inverters.
Two AC Outputs- The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus-II.
Virtually unlimited power thanks to parallel and three phase operation- Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide 25 kW / 30 kVA output power with 420 Amps charging capacity.
On-site system configuring, monitoring and control- Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface needed). Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
Remote configuring and monitoring- Install a Color Control GX or other GX product to connect to the internet. Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
SPECIFICATIONS
MultiPlus-II | 48/8000/110-100/100 | 48/10000/140-100/100 |
Power Control & Power Assist | Yes | |
Transfer switch | 100 A | 100 A |
Maximum AC input current | 100 A | 100 A |
INVERTER | ||
DC Input voltage range | 38 – 66 V | |
Output | Output voltage: 230 VAC ± 2% | |
Frequency: 50 Hz ± 0,1% (1) | ||
Cont. output power at 25°C (3) | 8000 VA | 10000VA |
Cont. output power at 25°C | 6400 W | 8000W |
Cont. output power at 40°C | 5500 W | 7000W |
Cont. output power at 65°C | 4000 W | 6000W |
Maximum apparent feed-in power | 8000VA | 10000VA |
Peak power | 15000 W | 18000 W |
Maximum efficiency | 95% | 96% |
Zero load power | 29 W | 38 W |
Zero load power in AES mode | 19 W | 27 W |
Zero load power in Search mode | 3 W | 4 W |
CHARGER | ||
AC Input | Input voltage range: 187-265 VAC | |
Input frequency: 45 – 65 Hz | ||
Charge voltage 'absorption' | 57,6 V | |
Charge voltage 'float' | 55,2 V | |
Storage mode | 52,8 V | |
Maximum battery charge current (4) | 110 A | 140 A |
Battery temperature and voltage sensor | Yes | |
GENERAL | ||
Auxiliary output | Yes (32 A) (50 A) | |
External AC current sensor (optional) | 50 A | 100 A |
Programmable relay (5) | Yes | |
Protection (2) | a - g | |
VE.Bus communication port | For parallel (not for 8k & 10k models) and three phase operation, | |
remote monitoring and system integration | ||
General purpose com. port | Yes, 2x | |
Remote on-off | Yes | |
Operating temperature range | -40 to +65°C (fan assisted cooling) | |
Humidity (non-condensing) | max 95% | |
ENCLOSURE | ||
Material & Colour | steel, blue RAL 5012 | |
Protection category | IP22 | |
Battery-connection | Four M8 bolts | |
230 V AC-connection | Bolts M6 | |
Weight | 42 kg | 49 kg |
Dimensions (hxwxd) | 642 x 363 x 206 mm | 677 x 363 x 206 mm |
STANDARDS | ||
Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, | |
EN-IEC 62109-1, EN-IEC 62109-2 | ||
EN 55014-1, EN 55014-2 | ||
Emission, Immunity | EN-IEC 61000-3-2, EN-IEC 61000-3-3 | |
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 | ||
Uninterruptible power supply | IEC 62040-1, AS 620401.1 | |
VDE-AR-N 4105, TOR-D4, AS/NZS 4777.2, NRS 097-2-1, UTE C15-712-1, C10/11, | ||
Anti-islanding | RD 1699-RD 413, G59/3-2, G83/2 | |
1)Can be adjusted to60Hz3) Non-linear load, crest factor 3:1 | ||
2)Protection key: 4) At 25°Cambient | ||
a)output shortcircuit5) Programmable relay which can be set for general | ||
b)overload alarm, DC under voltage or genset start/stop | ||
c)battery voltage too high function. AC rating: 230V / 4A, DC rating: 4A up to | ||
d)battery voltage too low 35VDC and 1A up to60VDC | ||
e)temperature too high | ||
f)230 VAC on inverter output | ||
g)input voltage ripple too high |
WARRANTY
Victron Energy warrants its products to be free from defects in workmanship and materials for a period of: Batteries: 2 year limited warranty Li-ion batteries: 3 year limited warranty All other products: 5 -year limited warranty.
NOTE:
The option of a 10-year limited warranty can only be applied during the actual purchase of the product.