Simarine Intergrated Mon Sys Quad Shunt 4x25A & 4xTank Module SI-SCQ25T


Price:
Sale price$422.00

Description

Active shunt for PICO battery monitor with 4x current sensors up to 25A each, combined with 3x voltage and 4x resistance inputs. For 12V and 24V system.

Looking for a highly versatile digital shunt module for monitoring smaller consumers like refrigerator and/or generators like solar, wind, hydro or shore power?

SCQ25T its an innovative combination of shunt, tank interface and voltage module with wide range of monitoring possibilities.

FEATURES 

  • Four current inputs for monitoring individual consumer and generator continuous currents up to 25A (35A peak) per input
  • Can handle 12V or 24V systems, (same voltage used per device)
  • Innovative protected architecture allows wiring in either negative (low) or positive (high) side. (same system used per device)
  • Very convenient for monitoring smaller consumers like refrigerator or generators like solar, wind, hydro or shore power.
  • Current channels can be combined for higher amperage, meaning 2 x 25A channels can be used for measuring up to 50A.
  • Up to five modules can be connected simultaneously to monitor up to 20 current channels with PICO Battery Monitor.
  • Assignable NO or NC output relay.

Plus it is equipped with:

Four resistance inputs for resistance-type tank level or temperature sensors and 

  • Three voltage inputs for voltage-type tanks sensors and battery voltages allows wide connection possibilities.
  • Assignable relay output NO or NC.

It receives its power to operate via the twisted pair communication cable from the splitter power block.

It is a versatile module for monitoring: 

  • Tanks of all descriptions
  • Temperature sensors
  • Battery voltage
  • Inclinometer inputs (x and Y need an input each)
  • AC current sense
  • Irradiation sensor for solar performance

 SPECIFICATIONS

Operating

Voltage Range

6-35 V

Temperature Range

-20 to +70°C

Power Consumption at 12V

Operating

3,5 mA

Current Measuring Channels

4

Current Measuring Range

Per Channel

0,01 – 50A

Accuracy

±0,6%

Resolution

0,01A

Sampling Rate

100ms

Maximal Current

Continuous

25A

Peak Current (<1 min)

35A

Peak Current (<5 sec)

50A

Voltage Drop at 25 A

35 mV

Maximal Voltage on Connections

35 V

Voltage Inputs

Range

0-35 V

Resolution

1 mV

Accuracy

±0,2%

Sampling Rate

100ms

Resistance inputs

Range

0 ohm – 65 kohm

Accuracy

±3,0%

Number of Connections

Total number of 7 voltage and resistance inputs + 4 x 25A current inputs

Tank level sensors

7 (both Voltage and Resistance). If resistance used for temperature then only 3 Tank Sensors

Temperature sensors

4 (resistance only)

 